Variable Speed electric rotary screw compressor; 0.66-1.65 m³/min (23-58 cfm) at 8 bar (116 psi), 450 Litres receiver.
Contact QCAS to confirm current pricing, availability and the right configuration for your application.
The Senator TSV11-8 is a variable speed electric, oil-lubricated rotary screw compressor with a 11 kW (15 hp) motor. Its published free air delivery is 0.66-1.65 m³/min (23-58 cfm) at 8 bar (116 psi).
The stationary receiver-mounted set includes a 450 Litres air tank. A refrigerant dryer and external filters are not included in this compressor listing.
The model code represents the standard 8 bar configuration. Other pressure settings (10 or 13 bar (145 or 189 psi)) are available through the supplier; air delivery changes with pressure. The quoted delivery figures apply at 8 bar.
Air delivery is reported to ISO 1217:2009; noise figures are measured at 1 metre. Installation and electrical requirements are detailed in the linked manufacturer brochure.
Source: Glenco Senator TSV Series specifications. Free air delivery is quoted for the standard 8 bar configuration.
Installed dimensions and weight require supplier confirmation because the current website and brochure provide different figures.
The Senator TSV11-8 lists free air delivery as 0.66-1.65 m³/min (23-58 cfm). Compare the flow at your required pressure and check the demand of equipment running at the same time.
The Senator TSV11-8 lists working pressure as 8 bar (116 psi). Use the working pressure needed at the point of use when comparing models. Ask QCAS to check the delivered flow at that pressure.
The Senator TSV11-8 lists electrical supply (manufacturer brochure) as 400 V, 3-phase, 50 Hz. Confirm the exact configuration and site services when requesting a quote.
The Senator TSV11-8 lists tank volume as 450 Litres. Check the mounting and receiver requirements against your installation space and air demand.
Compare the Senator TSV11-8 Rotary Screw when air demand changes materially during a shift. Give QCAS your minimum and peak demand, operating hours and pressure requirement so it can compare the unit’s operating range with a fixed-speed alternative.